What is the difference between ducted and non ducted fume hoods?

In the realm of laboratory safety equipment, fume hoods play a pivotal role in ensuring a secure environment for researchers and scientists. Two primary types dominate the scene: the Ducted Fume Hood and the non-ducted (or ductless) fume hood. Both serve the fundamental purpose of safeguarding users from hazardous fumes and vapors, yet they differ significantly in design, operation, and application.

Understanding the Ducted Fume Hood

The Ducted Fume Hood, as the name suggests, relies on a system of ducts to transport fumes, gases, and vapors away from the hood’s interior workspace.

Key Features of Ducted Fume Hoods:

  • Exhaust System: These hoods are connected to a complex network of ducts, which channel the contaminants to the outside atmosphere.
  • Ventilation Requirements: Due to their design, they require a continuous source of air from the laboratory, which is then expelled outside.
  • Broad Application: They can handle a wide variety of chemicals since they do not rely on filters to clean the air but rather expel the contaminants directly outside.

Understanding Non-Ducted Fume Hoods

Non-ducted fume hoods, often referred to as ductless or filter fume hoods, utilize activated charcoal and other specialized filters to clean and purify the air of contaminants. Instead of expelling the air outside, these hoods recirculate the cleaned air back into the laboratory.

Key Features of Non-Ducted Fume Hoods:

  • Filter System: The primary distinction is their reliance on filters to purify the air of contaminants. Over time, these filters become saturated and must be replaced.
  • Flexibility: Without the need for ductwork, these hoods offer more flexibility in placement within the laboratory. They can be relocated relatively easily.
  • No External Ventilation: Since they recirculate air, there’s no need for complex duct systems or external vents.

Comparing Their Functions and Applications

  1. Installation and Mobility: Non-ducted fume hoods have a clear advantage when it comes to installation and mobility. Without the necessity of ductwork, they are easier and quicker to install. Additionally, they can be moved more readily, offering greater flexibility for lab design and reconfiguration.
  2. Operating Costs: The Ducted Fume Hood typically has a higher initial installation cost due to the required ductwork and ventilation systems. However, non-ducted hoods might have higher long-term costs because of the need for regular filter replacements.
  3. Energy Consumption: Ducted hoods consistently expel conditioned laboratory air, meaning the building’s HVAC system must work harder to compensate, leading to potentially higher energy costs. In contrast, ductless hoods return conditioned air to the room, which can be more energy-efficient.
  4. Safety and Performance: Both types ensure safety when used correctly. However, the efficiency of non-ducted hoods depends on using the appropriate filter for the specific chemicals in use and ensuring timely filter replacements. Ducted hoods, given their direct expulsion of contaminants, can be considered more universally applicable.
  5. Environmental Considerations: Ducted hoods release contaminants directly into the atmosphere, though many systems have scrubbers or other treatments to reduce environmental impact. Non-ducted hoods, by using filters, retain contaminants, resulting in no direct release. However, saturated filters must be disposed of as hazardous waste.

Choosing Between Ducted and Non-Ducted Fume Hoods

When deciding which type of fume hood is most suitable for a particular laboratory, several factors should be weighed:

  • Chemical Usage: If a lab uses a wide variety of chemicals, a Ducted Fume Hood might be more suitable due to its broad applicability. Non-ducted hoods require specific filters for different chemicals, so labs with a limited or consistent chemical list might find them more practical.
  • Space and Infrastructure: For labs with limited space or those not equipped for extensive ductwork, non-ducted hoods offer an advantage.
  • Budget Constraints: Initial budgets might favor the non-ducted hood due to lower installation costs, but long-term operational expenses should also be factored into the decision.
  • Environmental Concerns: Organizations keen on reducing their environmental footprint might lean towards non-ducted hoods due to their lack of direct emissions.

In the realm of scientific discovery and exploration, safety remains paramount. Both the Ducted and Non-Ducted Fume Hoods serve the crucial role of protecting researchers from potential hazards.